Geotech | Σ-i Method Ground Reinforcement (Data Center Compatible)
Direct calculation of support strength from survey data. We achieve a robust foundation to support precision equipment through reliable structural design.
In data centers, differential settlement of the structure can have fatal impacts on precision equipment such as servers. Insufficient ground strength during foundation construction can lead to minute distortions and inclinations, posing a risk to operational stability. Therefore, selecting reinforcement methods based on accurate ground surveys is essential. The Geotech "Σ-i Method" directly calculates the allowable bearing capacity from SWS and dynamic cone penetration test results, supporting reliable structural design and thoroughly protecting the safety of buildings. 【Application Scenarios】 - Ground reinforcement during the construction of new data centers - Reducing the risk of differential settlement in critical facilities - Sites requiring rational design of data foundations 【Benefits of Implementation】 - Improved structural reliability through bearing capacity calculations based on objective data - Maintaining transparent records with digital construction management - Reducing construction-generated soil and costs by not using cement-based solidifying agents.
basic information
【Features】 - Technical specifications certified by the General Incorporated Foundation Japan Architectural Comprehensive Testing Institute (GBRC performance certification) - Objective bearing capacity calculations possible from converted N values of SWS tests and ram sounding tests - Excellent penetration thrust provided by the four excavation blades at the tip of the steel pipe and the integrally molded spiral wings - Rotational insertion method that suppresses construction-generated soil without using cement-based solidifying materials - A wide range of shaft diameters from φ89.1 mm to φ165.2 mm 【Our Strengths】 Geotech is a specialized company in ground engineering that offers one-stop services from ground investigation to reinforcement design and construction. Leveraging our extensive experience and solid technical skills, we support our clients' construction projects with rational engineering services directly linked to ground investigation data.
Price information
Delivery Time
Model number/Brand name
Ground reinforcement work
Applications/Examples of results
This construction method is optimal for small-scale buildings such as single-family homes, multi-family residences, and stores that are three stories or fewer, have a height of 13 meters or less, and a total floor area of 1,500 square meters or less (for single-story buildings, 3,000 square meters or less). It also accommodates foundation reinforcement for retaining wall structures with a height of 3.5 meters or less. Since it allows for design calculations directly linked to ground investigation data such as SWS tests, it is widely used at sites that aim for clear justification in building confirmation applications and structural calculations, as well as for rational and economical foundation reinforcement that minimizes excessive design.
catalog(4)
Download All Catalogs