Geocolumn | Ground reinforcement that clarifies structural calculation basis and eliminates excessive design.
Support structural design with established bearing capacity calculation formulas. The geo-column method eliminates overdesign and ensures a safe foundation plan.
The selection of ground reinforcement methods that are less likely to lead to excessive design in the basic plan is a challenge. The Geo-Column method is a soil-cement column improvement technique based on established bearing capacity calculation formulas, which clarifies the basis for structural calculations. It mechanically mixes and stirs locally generated soil with cement-based solidifying material slurry to form a homogeneous columnar improvement body. It addresses soft layers from GL-2m to GL-8m, penetrating the column tip into good ground with a cohesive soil N value exceeding 3 and a sandy soil N value exceeding 4 by more than 50 cm, ensuring the designed bearing capacity. Support for preliminary studies by specialized engineers from Geotech Co., Ltd. and real-time construction tracking using management devices provide consistent assistance from application response to on-site quality assurance.
basic information
The design calculation specifications for the geo-column method are for a standard cross-sectional area of 0.283 m² (column diameter φ600 mm) and a construction depth range from GL-2.0 m to GL-8.0 m. Penetration and anchoring into the supporting layer should be at least 50 cm into ground with a converted N value exceeding 3 for cohesive soil and exceeding 4 for granular soil. The design standard strength Fc is optimally calculated within the range of 400 to 1,500 kN/m² based on structural calculations. The amount of solidifying agent added is standardized at 300 kg/m³ or more for cohesive soil and 250 kg/m³ or more for granular soil, and all construction data will be measured and electronically stored and managed using an automatic monitoring device (such as GEO-MONITOR).
Price information
Delivery Time
Model number/Brand name
Ground reinforcement work
Applications/Examples of results
It is ideal for the foundation reinforcement of wooden, steel frame, and reinforced concrete (RC) houses, apartments, and stores that require logical support strength based on structural calculations (such as those with three stories or fewer, a height of 13 meters or less, and a total floor area of 1,500 m² or less). It rationally distributes axial forces and concentrated loads according to the layout plans of strip foundations or slab foundations. It is widely adopted as a standard column improvement method by architectural design offices, construction companies, and house manufacturers that want to smoothly prepare documents for submission to confirmation application agencies and structural examination reports.
catalog(4)
Download All Catalogs