Geo-column method | Structural calculation compliance and solid technical basis through ground reinforcement
Smooth suitability assessment and confirmation application! The Geo-column method ensures structural safety with strict construction management and clear bearing capacity calculations.
The GeoColumn method addresses the biggest concerns in ground reinforcement work: "compliance with structural calculations" and "objective proof of safety." Through in-house analysis and established bearing capacity calculation formulas, it is possible to calculate the allowable vertical bearing capacity with high precision. By mechanically mixing and stirring locally generated soil with cement slurry, a homogeneous soil-cement column is constructed. By anchoring the tip to a good ground with a cohesive soil N value exceeding 3 and a sandy soil N value exceeding 4 for more than 50 cm, the load of the structure is reliably transmitted to the supporting layer. Equipped with a technical backbone that can promptly respond to inquiries during confirmation application reviews and compliance assessments, it achieves efficiency in administrative responses and design work. With the technical support and strict quality control of Geotech Co., Ltd., as well as compliance with various ground guarantee insurances, a foundation structure that is trusted over the long term is established.
basic information
The basic specifications of the geo-column method are a standard diameter of φ600mm and a corresponding depth of approximately GL-2.0m to GL-8.0m. The criteria for the support layer fixation are a penetration of more than 50cm into soil with a converted N value of over 3 for cohesive soil and over 4 for granular soil. The design strength Fc is set between 400 and 1,500 kN/m2 based on structural calculations. The amount of cement-based solidifying agent added is standardized to be over 300kg/m3 for cohesive soil and over 250kg/m3 for granular soil, and the management system collects and records the pouring depth, rotation speed, pressure, and flow rate in real-time.
Price information
Delivery Time
Model number/Brand name
Ground reinforcement work
Applications/Examples of results
The explicit indication of allowable bearing capacity based on structural calculations is widely applicable to the foundation reinforcement of wooden, steel, and reinforced concrete (RC) single-family homes, apartments, and small retail stores (up to 3 stories, under 13 meters in height, and with a total floor area of less than 1,500 m²). It can be placed directly under strip foundations or slab foundations, allowing for a rational pile layout plan according to design loads. Since it facilitates the preparation of documents for submission to confirmation application agencies and specific review organizations, it is an optimal choice as a standard ground reinforcement method for architectural design offices and house manufacturers.