ETP-G Method | GBRC Certified Ground Reinforcement and Rotary Driven Steel Pipe Piles
ETP-G method with GBRC performance certification. High-reliability ground reinforcement that protects buildings through calculations based on SWS testing and ISO-compliant management.
The ETP-G method realizes safe ground reinforcement based on objective evidence. It is a rotary-driven steel pipe pile method that has obtained the GBRC performance certification (No. 09-19) from the Japan Building Disaster Prevention Association, deriving allowable vertical bearing capacity from clear calculation formulas based on SWS and SRS test data. The disc-shaped enlarged wings and excavation auxiliary bits demonstrate excellent penetration and bearing capacity, providing stable support for buildings up to three stories and with a total floor area of less than 1,500 square meters, as well as retaining walls. The method features zero residual soil through no-excavation construction, and it is also environmentally friendly with low noise and low vibration. Under ISO 9001-compliant quality management, qualified personnel strictly manage everything from pre-operation inspections to testing, delivering high-precision construction that eliminates the risk of differential settlement.
basic information
The ETP-G method is equipped with reliable technical specifications that comply with performance certification from third-party organizations. The outer diameter of the shaft steel pipe ranges from φ89.1mm to φ216.3mm (a total of 7 types), with a wall thickness of 3.2mm to 12.7mm, and materials used include STK400 and STK490. The disc-shaped enlarged wings at the tip come in 45 variations with diameters ranging from 223mm to 620mm (thicknesses of 12mm to 22mm, material SM490A, etc.). The applicable ground conditions are sandy soil (including gravelly soil) and clayey soil, and accurate calculation formulas based on SWS test and SRS test results are applied. The maximum construction depth is 19.2m (less than 130 times the pile diameter).
Price information
Delivery Time
Model number/Brand name
Ground reinforcement work
Applications/Examples of results
This construction method is ideal for building projects that require public standards and reliable support strength evidence. It targets small structures with three stories or fewer, a height of 13 meters or less, and a total floor area of 1,500 square meters or less (for single-story buildings, 3,000 square meters or less), as well as structures such as retaining walls, septic tanks, and billboards that are 3.5 meters or less in height. Since it has obtained a technical performance certification from a public agency (GBRC performance certification), the application for confirmation and technical explanations can proceed smoothly. Additionally, because it is a non-excavation, low-noise, and low-vibration rotary penetration method, it is widely used for ground reinforcement work in sites where excavated soil cannot be removed and in educational facilities and densely populated residential areas where environmental considerations are prioritized.
catalog(3)
Download All Catalogs