ジオテック Official site

Ground Improvement RES-P Method | Geotech Performance Certification

Eliminate the risks of weak ground. Ensure peace of mind in your home with RES-P.

In weak ground, there is a risk that ground subsidence and tilting can cause serious damage to buildings. The RES-P method is a performance-certified method developed by Geotech Co., Ltd. as a type of piled raft foundation method to address this issue. By driving slender steel pipes into the ground, it enhances the strength of the ground through the composite action between the ground and the pipes. This effectively prevents subsidence of residential foundations and protects the safety of homes in the long term.

Related Link - https://www.jiban.co.jp/service/kouji/resp/index.h…

basic information

We will enhance the bearing capacity of the ground. The design and construction management are consistently carried out by Soil Design Office Co., Ltd. During construction, we measure the penetration force of the pipes to ensure quality. We will install pipes in the ground at a certain ratio to increase the bearing capacity of the ground. This method is evaluated by the Building Center, making the application process with local authorities smooth and trustworthy for clients. We will reduce ground settlement. Pipes will be arranged at the foundation base according to the type of foundation (strip foundation or mat foundation), load level, and ground strength, and through the combined effect of the ground and pipes, we will aim to increase the bearing capacity of the ground and suppress settlement. Since it is not a pile foundation, reinforcement of the foundation is unnecessary, and it can be handled with a standard direct foundation. It can be designed as a flat ground reinforcement. We will carry out construction with low vibration and low noise. Due to the small diameter steel pipes, penetration into the ground is smooth. Therefore, compared to other methods, we can minimize the generation of vibration and noise. Construction is possible even on narrow land. The construction machine is based on a 2-ton vehicle, and there are no equipment other than materials, allowing for construction in confined spaces. No soil disposal is required.

Price range

Delivery Time

Model number/Brand name

RES-P method

Applications/Examples of results

Applicable Ground Clayey and sandy ground However, it cannot be applied to peat ground and ground that may liquefy during an earthquake. Note: For peat ground and ground with the potential for liquefaction, it is necessary for the designer of the target building to assess existing data such as regional ground maps or conduct separate ground investigations. SWS tests (and, if necessary, plate load tests, boring surveys, cone penetration tests, etc.) should be conducted at the planned construction site, and it can be applied to ground that meets the conditions shown in the table for ground strength up to 2 meters below the foundation. Long-term load capacity of the foundation and applicable ground strength Applicable Structures Small-scale buildings Buildings that meet all of the following conditions are eligible: 3 stories or fewer above ground Height of the building is 13 meters or less Total floor area is 1500 m² or less (for single-story buildings, 3000 m² or less) Small-scale works Applicable Foundation Structure It can be applied to strip foundations with a long-term design load of 50 kN/m² or less, or mat foundations with a load of 80 kN/m² or less.

Acquisition of performance certification for ground reinforcement construction "RES-P method" | Piled raft foundation method that prevents settlement through the combined action of small-diameter steel pipes and the ground | Geotec Co., Ltd.

PRODUCT

Distributors