SWS test recommended by academic societies, supported by empirical data and high-precision analysis.

This is the SWS test recommended in the "Guidelines for the Basic Design of Small-Scale Buildings" by the Architectural Institute of Japan. Two separate reports are submitted, one containing objective measurement data and the other focusing on ground diagnosis and analysis. Investigations and analyses are conducted by in-house ISO 9001 certified personnel, who measure screw point wear each time to ensure accuracy. Through advanced data analysis using the residential ground database "GEODAS," which contains 50,000 cases in the metropolitan area, we provide consistent support from the calculation of allowable stress in compliance with building code notifications to the proposal of optimal foundation specifications.

Related Link - https://www.jiban.co.jp/service/survey/tyosa02.htm

basic information

Using the JIS A 1221 standard equipment, it supports both manual and automatic operation. A load of up to 100 kg is applied to the rod head with a screw point attached to the tip to measure the penetration amount. After stopping penetration, rotation is applied, and the number of half turns (180 degrees rotation = 1) required to screw in 1 meter is measured. The sound transmitted from the rod and the penetration resistance accurately distinguish between sandy soil and clayey soil, allowing investigation up to a depth of about 10 meters in soft strata. In addition to displaying reference values for allowable bearing capacity and settlement, it also covers various additional specifications such as displaying elevation differences, collecting all-core samples using SWS penetration holes and SCSC-type samplers, confirming steel pipe pile support layers through PH-type SS tests, and surveying the current conditions of the site.

Price information

Please contact us.

Delivery Time

Model number/Brand name

SWS test

Applications/Examples of results

It applies to residential ground investigations in small-scale buildings, pre-evaluation of risks related to ground subsidence and differential settlement, and the selection of reinforcement works (such as the geo-column method, steel pipe pile method, and surface improvement method). It is extremely effective for understanding the current conditions of terrains where weak layers are a concern, such as low wetlands like former rice fields and old riverbeds, valley bottom plains, reclaimed land, sandbars, and cliffs. As a practical example, it has been introduced to prevent differential settlement that causes tilting in one direction and distortion of components, and is utilized as a design basis to avoid serious building damage such as issues with window frames, reduced airtightness, structural corrosion, shortened building lifespan, and significant damage to seismic performance. It also contributes to preventing mental stress and sleep disorders in residents caused by floor tilting.

Related Videos

Ground investigation service "Swedish-style sounding test"

PRODUCT

Distributors