Ground Reinforcement RES-P Method for Public Facilities | Geotech
Using the RES-P method, which has obtained architectural technical performance certification, to extend the lifespan of public facilities and reduce settlement risks.
This is a ground reinforcement method that has obtained a building technology performance certificate, aimed at achieving the long lifespan of public facilities and reducing maintenance costs. Geotech's RES-P method involves driving slender steel pipes into soft ground, which suppresses settlement through complex interactions with the ground. This prevents risks such as increased repair costs due to differential settlement and restrictions on facility use. 【Usage Scenarios】 - New construction of public facilities - Measures for extending the lifespan of existing facilities - Construction on soft ground 【Benefits of Implementation】 - Ensures long-term stability of buildings - Reduces the risk of differential settlement - Controls maintenance management costs
basic information
【Features】 - This is a highly reliable construction method that has obtained the Building Technology Performance Certification (Performance Evaluation No. 04-02). - It enhances bearing capacity through the composite action of the ground and the pipes by driving slender steel pipes into soft ground. - It is a type of piled raft foundation method and is classified as a planar ground reinforcement method. - The slender steel pipes used are treated for rust prevention, ensuring long-term durability. - It is suitable for cohesive and sandy soil, with a maximum reinforcement depth of 14 meters. 【Our Strengths】 Geotech provides "total ground services," offering a one-stop solution for all ground-related tasks, from ground surveys to ground reinforcement design and construction, as well as settlement correction work for existing buildings. With extensive experience and reliable technology, we contribute to the longevity of public facilities.
Price range
Delivery Time
Model number/Brand name
RES-P method
Applications/Examples of results
It is ideal for reinforcing the foundation ground of small-scale buildings, boasting a rich track record of over 60,000 improvement projects to date. The applicable range is limited to buildings with up to three stories above ground, a height of 13 meters or less, and a total floor area of 1,500 m² or less. The foundation structure can be applied to slab foundations with a long-term design load of 80 kN/m² or less, or to strip foundations with a load of 50 kN/m² or less. As practical examples of achievements, it demonstrates outstanding advantages in sites where no soil is generated due to non-excavation construction, eliminating disposal costs, sites that can be handed over to the next process immediately with zero curing time, and tight construction projects in narrow spaces or near retaining walls, utilizing low vibration and low noise specifications.