ユニオンシステム Official site

Seismic Diagnosis Software 'Super Build / RC Diagnosis Op.1'

This is an option for conducting seismic diagnosis of reinforced concrete buildings, known as 'RC Diagnosis'.

"Super Build/RC Diagnosis Op.1" is an optional program for conducting seismic assessments of buildings that consider reinforcement using framed steel brace structures, as part of the "Super Build/RC Diagnosis." It complies with the "2001 Revised Edition Guidelines for Seismic Retrofit Design of Existing Reinforced Concrete Buildings" and the "2009 Revised Edition Guidelines for Seismic Retrofit Design of Existing Steel Reinforced Concrete Buildings" published by the Japan Architectural Disaster Prevention Association. 【Features】 - Reinforcement using framed steel brace structures - Seismic assessment considering reinforcement members - Calculation of ultimate strength and F index for each failure mode For more details, please contact us or download the catalog.

Earthquake Resistance Diagnosis Software 'Super Build / RC Diagnosis Op.1' Product Detail Page

basic information

**Features** [Reinforcement with Framed Steel Brace Structure] - We handle X-type, K-type, and Mansard-type framed steel brace structures as reinforcement members. - Input is performed on the anchor for head-studded construction, and the failure mode "Type II" (joint failure) is examined. [Seismic Diagnosis Considering Reinforcement Members] - Equivalent wall thickness is calculated for the ultimate strength, F index, strength contribution coefficient, and rigidity evaluation of the framed steel brace structure, conducting seismic diagnosis considering reinforcement members. - A series of processes for seismic reinforcement design can be performed, making it easy to simulate reinforcement using framed steel brace structures. [Calculation of Ultimate Strength and F Index by Failure Mode] - Calculate the local strength and F index for the failure modes indicated in the "Seismic Retrofit Guidelines": "Type I" (steel brace failure), "Type II" (joint failure), "Type III" (overall bending failure), "Type IV" (column brittle failure), and "Others" (foundation rotation failure). - Ultimate strength and F index are calculated based on the direction of applied force. ● For more details, please contact us or download the catalog.

Price information

Please contact us.

Delivery Time

Applications/Examples of results

For more details, please contact us or download the catalog.

Seismic Reinforcement and Diagnosis Software 'Super Build / RC Diagnosis Op.1'

PRODUCT

Distributors

Recommended products