EPJ Official site

NETIS Tome Taro® CAD Data List

You can download CAD data for 【Tome TaroⓇ】.

When using the CAD data download, please check the following precautions in advance. From the moment you use the provided data, you are considered to have agreed to the following precautions. Thank you for your understanding. <Precautions> ◆ The CAD data is to be used solely for the purpose of considering the adoption of our products, and should not be used for any other purpose. ◆ The copyright and ownership of the CAD data are owned by EPJ Corporation, and you may not reuse (repurpose) the data in digital or print media without the consent of EPJ Corporation. Furthermore, please refrain from lending or transferring it to third parties. ◆ Please refrain from making any unauthorized modifications or alterations to the CAD data. ◆ Please be aware that we cannot be held responsible for any results arising from the use of the CAD data. ◆ The published data may be updated or deleted without prior notice due to product improvements or version upgrades. Thank you for your understanding.

TOMETARO PAGE

basic information

Tome TaroⓇ【Hand Hole/Cable Penetration Construction】 ■ Two-layer filling (FEP pipe/Bell mouth) 【(Backup material) + Tome Taro filling】 ■ Two-layer filling (FEP pipe/Aqua connector) 【(Backup material) + Tome Taro filling】 ■ Three-layer filling (FEP pipe/Bell mouth) 【(Backup material) + Tome Taro filling + Hatsu-reiru finish】 ■ Three-layer filling (FEP pipe/Aqua connector) 【(Backup material) + Tome Taro filling + Hatsu-reiru finish】 Contact: EPJ Corporation TEL: 03-5643-8137 FAX: 03-5643-8138 Email: info@epj-inc.co.jp

Price range

Delivery Time

Applications/Examples of results

For more details, please refer to the catalog or feel free to contact us.

Related Videos

Line up(4)

Model number overview
TM-B5 Tome Taro 5kg Cup
TM-B1 Tome Taro 1kg Cup
SU-1 (Optional) Suutaro Backup Material 20×70×1,000L
HT-1K (Optional) Hatsu-reiru 1kg bag

Tome Taro® Non-drying Polyolefin-based One-component Water Stop Putty - Non-curing Water Stop Material -

PRODUCT

Tome TaroⓇ ser. Premixed Mortar Hatsu Re-ru (Chipping Mortar)

PRODUCT

[Adoption Results] Tome Taro Water Stop / Flood Prevention and Water Resistance Promotion Project Edition

OTHER

[Adoption Results] Tome Taro Water Stopping / Flood Prevention and Waterproofing Works (Public Sector Edition)

OTHER

【Adoption Results】 Tome Taro Water Stop / Leak Prevention (Renewable Energy Edition)

OTHER

CAD data(12)

Model number overview File
Drawing: Tome Taro Filling Cross Section (2 Layers) Bell Mouth Specification Non-drying polyolefin-based single-component water-stopping putty "Tome TaroⓇ" Furukawa Electric Co., Ltd. underground cable protection pipe "Eflex" This is a cross-sectional view of the two-layer filling at the handhole wall surface/cable penetration section (bell mouth).
  • 2D pdf ( 460KB)
Drawing: Tome Taro Filling Cross Section (2 Layers) Bell Mouth Specification Non-drying polyolefin-based single-component water-stopping putty "Tome TaroⓇ" Furukawa Electric Co., Ltd. underground cable protection pipe "Eflex" This is a cross-sectional view of the two-layer filling at the handhole wall surface/cable penetration section (bell mouth).
  • 2D jww ( 0B)
Drawing: Tome Taro Filling Cross Section (2 Layers) Bell Mouth Specification Non-drying polyolefin-based single-component water-stopping putty "Tome TaroⓇ" Furukawa Electric Co., Ltd. underground cable protection pipe "Eflex" This is a cross-sectional view of the two-layer filling at the handhole wall surface/cable penetration section (bell mouth).
  • 2D dxf ( 0B)
Drawing: Tome Taro Filling Cross Section (2 Layers) Aqua Connector® Specification Non-drying polyolefin-based single-component waterproofing putty "Tome Taro®" Furukawa Electric Co., Ltd. underground cable protection pipe "Eflex" This is a cross-sectional view of the two-layer filling at the handhole wall/cable penetration (Aqua Connector).
  • 2D pdf ( 454KB)
Drawing: Tome Taro Filling Cross Section (2 Layers) Aqua Connector® Specification Non-drying polyolefin-based single-component waterproofing putty "Tome Taro®" Furukawa Electric Co., Ltd. underground cable protection pipe "Eflex" This is a cross-sectional view of the two-layer filling at the handhole wall/cable penetration (Aqua Connector).
  • 2D jww ( 58KB)
Drawing: Tome Taro Filling Cross Section (2 Layers) Aqua Connector® Specification Non-drying polyolefin-based single-component waterproofing putty "Tome Taro®" Furukawa Electric Co., Ltd. underground cable protection pipe "Eflex" This is a cross-sectional view of the two-layer filling at the handhole wall/cable penetration (Aqua Connector).
  • 2D dxf ( 122KB)
Drawing: Tome Taro Filling Cross Section (3 Layers) Bell Mouth Specification Non-drying polyolefin-based one-component waterproofing putty "Tome Taro" + "Hatsureru" Furukawa Electric Co., Ltd. Underground cable protection pipe "Eflex" This is a cross-sectional view of the three-layer filling at the handhole wall/cable penetration section (bell mouth).
  • 2D pdf ( 493KB)
Drawing: Tome Taro Filling Cross Section (3 Layers) Bell Mouth Specification Non-drying polyolefin-based one-component waterproofing putty "Tome Taro" + "Hatsureru" Furukawa Electric Co., Ltd. Underground cable protection pipe "Eflex" This is a cross-sectional view of the three-layer filling at the handhole wall/cable penetration section (bell mouth).
  • 2D jww ( 72KB)
Drawing: Tome Taro Filling Cross Section (3 Layers) Bell Mouth Specification Non-drying polyolefin-based one-component waterproofing putty "Tome Taro" + "Hatsureru" Furukawa Electric Co., Ltd. Underground cable protection pipe "Eflex" This is a cross-sectional view of the three-layer filling at the handhole wall/cable penetration section (bell mouth).
  • 2D dxf ( 163KB)
Drawing: Tome Taro Filling Cross Section (3 Layers) Aqua Connector® Specification Non-drying polyolefin-based single-component water stop putty "Tome Taro" + "Hatsureru" Furukawa Electric Co., Ltd. Underground cable protection pipe "Eflex" This is a cross-sectional view of the three-layer filling at the handhole wall and cable penetration section (Aqua Connector).
  • 2D pdf ( 470KB)
Drawing: Tome Taro Filling Cross Section (3 Layers) Aqua Connector® Specification Non-drying polyolefin-based single-component water stop putty "Tome Taro" + "Hatsureru" Furukawa Electric Co., Ltd. Underground cable protection pipe "Eflex" This is a cross-sectional view of the three-layer filling at the handhole wall and cable penetration section (Aqua Connector).
  • 2D jww ( 66KB)
Drawing: Tome Taro Filling Cross Section (3 Layers) Aqua Connector® Specification Non-drying polyolefin-based single-component water stop putty "Tome Taro" + "Hatsureru" Furukawa Electric Co., Ltd. Underground cable protection pipe "Eflex" This is a cross-sectional view of the three-layer filling at the handhole wall and cable penetration section (Aqua Connector).
  • 2D dxf ( 143KB)

Distributors

A manufacturer specialized in planning, design, and engineering. We focus on product development to solve various issues at construction sites, providing innovative, cutting-edge, and ecological products. Please feel free to contact us.

Recommended products