Ground reinforcement work [Performance Guarantee Method] ETP-G Method
Rotary driven steel pipe piles suitable for small-scale buildings.
Leading Edge Wing Easy to penetrate with a simple shape. Design possible with simple testing Design possible with SWS testing and ram sounding testing. Low noise, low vibration, and no spoil, environmentally friendly Extremely low vibration and noise, considerate of the surrounding environment, with no generation of residual soil, making it an environmentally friendly clean construction method.
basic information
Types of Applicable Ground Ground at the tip of the foundation pile: Sandy ground (including gravelly ground) and clayey ground Ground surrounding the foundation pile: Sandy ground and clayey ground Maximum Construction Depth The length of the pile should be no more than 130 times the diameter of the foundation pile body. However, for steel pipes with an outer diameter of 89.1mm to 190.7mm, the maximum construction depth shall be the smaller of 19.2m from the reinforcement construction ground level or 130 times the outer diameter of the steel pipe.
Price range
Delivery Time
Model number/Brand name
ETP-G Method
Applications/Examples of results
Applicable building scale: Up to 3 stories above ground Height of the building not exceeding 13m Total floor area not exceeding 1500m2 (for single-story buildings, not exceeding 3000m2) Retaining walls (not exceeding 3.5m in height), as well as structures such as septic tanks and billboards.