ジオテック Official site

[For the Telecommunications Industry] RES-P Method Ground Reinforcement Work | Geotec Co., Ltd.

Supporting the base station with planar ground reinforcement that has obtained architectural technical performance certification.

In the telecommunications industry, especially in the installation of base stations, long-term stable operation and compatibility with the ground conditions of the installation site are required. Base stations need a robust support foundation that can withstand heavy objects such as radio towers and communication equipment, as well as natural environments like wind, rain, and earthquakes. Ground subsidence and tilting pose direct risks of communication failures and equipment malfunctions. Our RES-P method is a ground reinforcement technique that has obtained architectural technology performance certification, and it prevents building subsidence even on soft ground through the combined effects of pipes and the ground, contributing to the stable installation of base stations. 【Usage Scenarios】 - New installation of base stations - Improvement of seismic resistance of communication infrastructure - Installation of communication equipment on soft ground 【Benefits of Implementation】 - Long-term stable operation of base stations - Reduction of communication failure risks - Flexible response to ground conditions at installation sites

Related Link - https://www.jiban.co.jp/service/kouji/resp/index.h…

basic information

【Features】 - This is a highly reliable construction method that has obtained the Building Technology Performance Certification (Performance Evaluation No. 04-02). - Thin steel pipes (outer diameter 48.6mm, wall thickness 2.4mm) are driven into weak ground, enhancing bearing capacity through the composite action of the ground and the pipes. - It is classified as a surface ground reinforcement method and performs ground improvement similar to surface modification methods. - Applicable ground types include cohesive soil and sandy soil, with a maximum reinforcement depth of up to 14m. - During construction, the penetration depth and resistance are accurately recorded through rotary insertion. 【Our Strengths】 Geotech provides "total ground services," offering a one-stop solution for all tasks related to "ground," including ground surveys and reinforcement design/construction for new buildings, as well as settlement correction work for existing structures. With extensive experience and reliable technology, we create the future of cities from the ground up. Design, construction, and supervision are centralized, ensuring a robust quality management system under the guidance of Soil Design Office Co., Ltd.

Price range

Delivery Time

Model number/Brand name

RES-P method

Applications/Examples of results

It is optimal for reinforcing the foundation ground of small-scale buildings, boasting a rich track record of over 60,000 improvement projects to date. The applicable range is limited to buildings with up to three stories above ground, a height of 13 meters or less, and a total floor area of 1,500 m² or less. The foundation structure can be applied to slab foundations with a long-term design load of 80 kN/m² or less, or strip foundations with 50 kN/m² or less. As practical examples of achievements, it demonstrates outstanding advantages in sites where no soil is generated due to non-excavation construction, eliminating disposal costs, sites that can be handed over to the next process immediately with zero curing time, and tight construction projects in narrow spaces or near retaining walls, leveraging low vibration and low noise specifications.

Distributors

Recommended products