All products and services
1~30 item / All 32 items
-
Exposed Type Column Base Method - High Base NEO Method <High Strength Column Applicable Type>
A new type has been added to the High Base NEO construction method (BCJ Evaluation ST0059-08)!
last updated
-
Smart Dia II Method (Applicable Range 150mm)
Supports a maximum aperture of 150mm! Introducing the diaphragm method we use.
last updated
-
Exposed Type Column Base Construction Method High Base NEO Method <LB Type>
Introduction to the design flow of base plates and exposed type column bases!
last updated
-
Wiring, air conditioning, and seismic reinforcement! Senkusia's free access floor.
Approximately 60 years of rich experience! Store wiring for computer equipment, communication, and office automation devices under the floor with a raised floor! For offices, data centers, and clean rooms!
last updated
-
Earthquake measures for factories and warehouses! Consistent support for seismic measures without stopping operations.
Are your factory and warehouse earthquake measures in place? We provide comprehensive support from on-site surveys to seismic assessments and reinforcement construction! We propose safe and secure seismic reinforcement.
last updated
-
Smart Chronos II Method
Level adjustment of the joining hardware is possible! Work in narrow areas on the exterior wall can also be done easily.
last updated
-
Bearing Diabase Method
Integrating the base plate, diaphragm, and reinforcement ribs! Contributes to the compactness of the foundation!
last updated
-
If you are struggling with seismic reinforcement of steel structures, contact Senkushia for total support.
From on-site surveys to seismic assessments and reinforcement work, we provide consistent support. With our original construction methods, we propose safe and reliable seismic reinforcement in a short construction period.
last updated
-
Steel beam penetration hole reinforcement method "PosiRing Method" [Shortens steel fabrication time]
A penetration hole reinforcement method that emphasizes welding volume and workability for small to medium-sized properties with many penetration holes below φ300, aiming for labor-saving efficiency!
last updated
-
High shear strength high base standardization | Shear cutter high base method
The Shiakotta High Base Method is a product capable of handling large shear forces that could not be addressed by previous high base methods.
last updated
-
Low rigidity column bases, PIN base method, suitable for the column bases of low-rise buildings.
It is suitable as a column base for low-rise buildings such as single-story and two-story structures. Since the foundation shape can be simplified, it reduces the total cost compared to conventional pinned column bases!
last updated
-
Obtained construction technology examination certification" Non-welded brace reinforcement "Smart Attach Method
The Smart Attach method is a non-welding, short-term bracing reinforcement method that replaces traditional seismic reinforcement.
last updated
-
Fixture-compatible OA floor "Lacloc"
Simple earthquake measures with fixed installation! Fastening devices that directly secure furniture to OA floor panels.
last updated
-
Steel frame seismic reinforcement method "Smart Fit Method"
The concept is "minimizing the impact on productivity." Through refinement, it has become possible to perform non-welding work on existing structures when they are H-beams.
last updated
-
<Minister of Land, Infrastructure, Transport and Tourism Certified Material> Pile Head Joint Method "Joint Coupler Method"
Reduction in the number of pile head connection bars is possible! A pile head connection method with significant load-bearing capacity: "Joint Coupler Method."
last updated
-
Exposed Type Column Base Method High Base NEO Method *Structural Member
Emphasizing rationalization and burden reduction in building structural design!
last updated
-
Seismic Steel Plate Damper / Extendum 【Suppresses Earthquake Shaking!】
It can absorb energy during an earthquake! This is a compact steel damping device that suppresses the shaking of earthquakes.
last updated
-
Steel beam penetration hole reinforcement method High Ring III method [Freedom in equipment planning]
Relax the restrictions on the diameter and position of through holes to increase the flexibility of equipment planning! Standardize high rings and aim for the rationalization of steel frame production.
last updated
-
Seismic resistance/free rack floor of the data center [fixing server racks]
Earthquake resistance measures for data centers: Easily secure servers to protect them from earthquakes!
last updated
-
Seismic isolation floor / Skid / Skid II [Existing buildings are also OK, lightweight, excellent workability]
High-performance two-dimensional seismic isolation floor of free access floor (raised floor) that achieves lightweight, ease of construction, and low cost.
last updated
-
Floor-mounted air conditioning floor / Beautiful breeze [Providing a comfortable space with airflow from under the floor]
The airflow from under the floor prevents the wind from directly hitting the skin, making it comfortable! An environmentally friendly OA floor that improves comfort and energy efficiency by evenly regulating indoor temperature.
last updated
-
Smart Dia II Method
Reduction of steel frame manufacturing labor and shortening of construction period achieved! Replacement from conventional methods is possible.
last updated
-
Hydraulic damping damper / High-rise dam【Oil damper that responds to wind sway】
Hydraulic damping device that reduces building sway to enhance safety and livability.
last updated
-
Free access floor / wood core steel floor [lightweight, excellent walkability]
This floor panel not only reduces weight with wood core material but also contributes to CO2 fixation. It is lightweight, easy to handle, and offers excellent walking comfort.
last updated
-
Structural member/SRC super high base method
Based on abundant experience, we support the pursuit of functional and economical new seismic-resistant architecture.
last updated
-
Flooring/Cleanroom Floor [For manufacturing factories of precision equipment such as semiconductors]
Use flooring designed for clean rooms in clean rooms!
last updated
-
Free access floor / office floor [For raised floors, choose Senkushia]
Underfloor wiring for computer equipment, communications, and office automation devices with a raised floor.
last updated
-
Flooring/Computer Room Floor [Capable of storing many wires]
Neatly store more wiring and cables under the floor!
last updated
-
High-base construction method
A pioneer of exposed column foundation methods with over 30 years of sales experience.
last updated
-
Free access floor/steel panel [recyclable]
In the computer room floor! All-steel free access floor.
last updated